Arrived on site and found condenser fan running without compressor. Tested capacitor and found it to have no measurable capacitance. Found drain line to be clear. Condenser coil was extremely dirty. Recommended cleaning to promote heat exchange and reduce stress on the system. Found extremely dirty blower wheel with a large amount of bacterial growth on the blower wheel housing. Discussed with homeowner options for getting the unit back up and running , as well as cleaning the blower wheel and housing. Homeowner elected to replace capacitor and go forward with maintenance. Performed maintenance. Customer did not have filters to change at this time, but stated she would change them soon. 1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspec