Today, I arrived on site to perform maintenance on the HVAC system. Overall Condition: * Equipment condition rated as fair. * Package unit located at the side of the house. Indoor Unit Details: * Filtration system features a pleated 1" filter, replaced today. * Filter size is 20x20x1. * Indoor coil condition is fair and clean. Outdoor Unit Details: * Outdoor coil condition rated as fair. Electrical Components: * Blower motor, compressor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring tested and found to be working properly within manufacturer's recommended specs and amperages. Inspections: * Blower wheel, primary drain pan, and ductwork in poor condition and not working properly at this time. * No issues found with carbon monoxide levels. * Return air temperature measured at 73.0 degrees Fahrenheit. * Supply air temperature measured at 55.0 degrees Fahrenheit. Condensate Drain System: * Cleared drain line and cleaned out primary pan. * Safety switc