5402 Tower Rd
Tallahassee, FL 32303
850-562-3132

Job Locations
for crawfordville, fl


Map of Crawfordville FL
Aidan D.

Aidan D.


Job Checkin

Today, I arrived on site to perform maintenance on the HVAC system. Overall Equipment Condition: * Condition rated as fair. Indoor Unit Details: * Located in a closet. * Services the whole home. * Filtration system: Respicare. * Customer will provide their own filters for replacement. Indoor Coil Condition: * Condition rated as fair. Outdoor Unit Details: * Located in the back yard. * Type: Straight Cool. * Condition rated as fair. Electrical Component Status: * Tested and inspected components working properly: * Blower Motor * Condenser Fan Motor * Compressor * Blower Run Capacitor * Fan Run Capacitor * Contactor * Electrical Wiring Component Inspection: * Good condition and working properly: * Blower Wheel * Secondary Drain Pan * Primary Drain Pan * Electrical Wires secured * No components found in poor condition. Temperature Readings: * Return Air Temperature: 76.0 degrees Fahrenheit. * Supply Air Temperature: 56.0 degrees Fahrenheit. Condensate Drain S