Today I arrived on site and performed a summer time maintenance on your HVAC equipment. **Indoor Unit (Air Handler in Garage/Attic):** * Observed the indoor unit to be in fair condition. * Verified pleated 1" filter (20x25) is in place. * Noted the indoor coil is dirty and recommend a duct cleaning. **Outdoor Unit (Heat Pump on Side of House):** * Observed the outdoor coil to be in good and clean condition. **Electrical Components:** * Tested and confirmed the following components are working properly within manufacturer's specifications: * Blower Motor * Condenser Fan Motor * Compressor * Blower Run Capacitor * Compressor Run Capacitor * Fan Run Capacitor * Compressor Start Capacitor * Contactor * Electrical Wiring **System Components:** * Inspected and confirmed the following components are in good working order: * Blower Wheel * Secondary Drain Pan * Primary Drain Pan * Electrical Wires