Today, I arrived on site to perform a summer time maintenance on the HVAC equipment. Overall Equipment Condition: Fair condition noted for the system. Indoor Unit: Located in the attic, type: furnace. Services whole home efficiently. Washable filter was cleaned today. Filter size: 20x25x5. Indoor coil condition: fair and clean. Outdoor Unit: Positioned in the back yard, type: straight cool. Outdoor coil condition: good and clean. Electrical Components: All tested components are functioning properly within manufacturer specifications: Blower Motor Condenser Fan Motor Compressor Compressor Run Capacitor Fan Run Capacitor Compressor Start Capacitor Contactor Electrical Wiring No components were found not working properly. Inspected Components: Good condition and functioning properly: Blower Wheel Primary Drain Pan Electrical Wires secured No components were found in poor condition. Temperature Readings: Return Air Temperature: 74.0 Degrees Fahrenheit. Supply Air Temperature: 55.0 De