Today, I arrived on site to perform summer maintenance on the HVAC equipment. Overall Equipment Condition: * Good condition noted throughout the system. Indoor Unit: * Located in the closet; air handler type. * Services the whole home. * Pleated 1" filter checked today. * Filter size is 16x21; clean condition observed. * Indoor coil is good and was brush cleaned today. Outdoor Unit: * Located on the side of the house; heat pump type. * Outdoor coil is in good condition and was cleaned today. Electrical Components: * Blower Motor, Inducer Draft Motor, Heat Strip Kit, Condenser Fan Motor, Compressor, Blower Run Capacitor, Compressor Run Capacitor, Fan Run Capacitor, Contactor, and Electrical Wiring tested and are working properly within manufacturer specifications. Inspected Components: * Blower Wheel, Primary Drain Pan, Secondary Drain Pan, and Electrical Wires secured; all in good condition. * No components found in poor condition. Temperature Readings: * Return Air Temperature: