Today I arrived on site and performed a summer tune-up on your system. Here’s a summary of the work completed: **Indoor Unit Service:** * Replaced the pleated 1" filter (size 14x14). * Observed the indoor coil to be in fair condition. **Outdoor Unit Service:** * Observed the outdoor coil to be in fair condition. * Verified the following electrical components are working within manufacturer specifications: Blower Motor, Condenser Fan Motor, Compressor, Blower Run Capacitor, Compressor Run Capacitor, Fan Run Capacitor, Compressor Start Capacitor, Contactor, and Electrical Wiring. * Confirmed the following components are in good working condition: Blower Wheel, Secondary Drain Pan, Primary Drain Pan, and Electrical Wires Secured. **System Checks & Adjustments:** * Cleaned out the condensate pump and cleared the drain line. * Measured a return air temperature of 77.0°F and a supply air temperature of 57.0°F. * Dusted the thermostat and return grills. * Restored powe