Today I arrived on site and performed a summer time maintenance on your HVAC equipment. **Indoor Unit (Attic):** * Replaced the pleated 1" filter (20x20x1). * Observed the indoor coil to be in fair condition. **Outdoor Unit (Side of House):** * Observed the outdoor coil to be in fair condition. * Tested and inspected the blower motor, compressor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring; all are working properly within manufacturer's specifications. * Inspected the blower wheel, primary drain pan, electrical wires, secondary drain pan, and ductwork; all are in good condition and working properly. **Condensate Drain System:** * Cleared the drain line. * Cleaned out the primary and secondary pans. * Tested the safety switch. **Measurements:** * Return air temperature: 75.0°F. * Supply air temperature: 59.0°F. **Other:** * Restored power to the units. **Recommendations:** * Duct cleaning is recommended. Tallahassee F