Completed an AC tune-up on a Lennox system. Used a manifold gauge to check refrigerant levels and added R-410A as needed. Cleaned both condenser and evaporator coils for optimal heat exchange. Inspected and secured electrical connections. Lubricated motor and blower bearings. Replaced the air filter and adjusted the thermostat for precise temperature regulation. Tested the system to confirm peak performance and cooling efficiency.