4127 E University Dr
Phoenix, AZ 85040
480-839-0082

Local Reviews
for apache junction, az


Job Locations
for apache junction, az

Matthew B.

Matthew B. Job Checkin

I performed an AC check on both systems. The living room system is not performing as well as the master bedroom. The homeowner is thinking of changing the system out.


Matthew B.

Matthew B. Job Checkin

DESCRIPTION Preferred Cool Home Membership - 1 System Includes two maintenance visits per year for 1 system Front of the line, priority service over everyone else, guaranteed service within 24 hours Discounted $37 diagnostic fee (versus regular diagnostic fee of $97) 100% of your protection plan goes toward your future system replacement (capped at $1,000) https://www.idealairaz.com/flipbook/cool-home/?page=1


Matthew B.

Matthew B. Job Checkin

Performed an AC check on the system. I found the capacitor for the compressor testing bad and the blower motor capacitor tested bad as well. The contactor is burnt and needs to be replaced. The Schrader valves for the service ports are leaking Freon. The homeowner is going to get proposals for system replacement and is interested in a multi head mini split.


Alex W.

Alex W. Job Checkin

I replaced sensors, float switch and eev stepper motor on evap coil. Installed chicken wire at supply drop to prevent critters from entering unit. Cleaned outdoor condenser coil and adjusted charge to name plate sub cooling. System is now operating fine at this time.


Ryan C.

Ryan C. Job Checkin

Performed 1st year cool home maintenance on Bosch package unit on the ground. No found issues at time of visit. System operating properly at manufacturer specifications.


Matthew B.

Matthew B. Job Checkin

Performed a platinum membership visit. The unit is operating properly at this time. This was the last visit and it is time to renew the plan. I attached a proposal that will renew the membership and start when this membership expires.


Matthew B.

Matthew B. Job Checkin

Performed an AC check on both systems. The units are operating properly.


Ryan C.

Ryan C. Job Checkin

Performed cool home maintenance check. System operating properly at the time.


Matthew B.

Matthew B. Job Checkin

The thermostat had lost connectivity to the router. I reconnected the thermostat and verified heat pump settings. I showed the tenant how to reestablish connection on his phone. The unit was going out on high head pressure due to the very dirty filter. I told the tenants they should change the filter every 30 days. I verified operations. Includes two maintenance visits per year - 1 System Front of the line, priority service over everyone else, guaranteed service within 24 hours Discounted $37 diagnostic fee (versus regular diagnostic fee of $97) 100% of your protection plan goes toward your future system replacement (capped at $1,000) https://www.idealairaz.com/flipbook/cool-home/?page=1


Matthew B.

Matthew B. Job Checkin

Preformed tune up on package unit, since last repair unit has been working well the homeowner said. I looked everything over and it seems to be in good condition for the age. There was a couple items that we recommended, one thing is we should do an indoor coil clean as it’s getting dirty. Dirt does make it past filters and it should be cleaned periodically . The other item is the drain line has no safety switch or drain clean out. If the drain backs up this prevents water coming in home. It’s very common to have these on units as most new units have them installed from the start. Other wise everything looks pretty good. Homeowner is 98 and normally goes over stuff like this with her daughter. I told her it’s no issue at all and if they decide to go with my recommendations to just give us a call and we will get it done for her. Unit running at departure.


Matthew B.

Matthew B. Job Checkin

Dispatch said no charge for service call. Arrived to home and customer said unit would intermittently turn off. I found several items that I spoke to homeowner about such as the thermostat was not clipped into subplate which could cause issues. Also, the starting amps were exceeding manufacturer specs which is causing damage to compresser and raise power bills and lastly the primary cause is a bad Contactor. The voltage was there but it didn’t always make contact so compresser would not come on. Homeowner approved all repairs and got them signed up with a PMA and recommended calling in to get the maintenance scheduled here in the near future. Unit running at departure with a 21 degree TD


Chris M.

Chris M. Job Checkin

Blower door test in AJ


Chris M.

Chris M. Job Checkin

Blower door test in Apache Junction


Matthew B.

Matthew B. Job Checkin

I verified the house unit is splitting 20°. The unit for the shop has a bad blower motor. The homeowner is going to call back if he wants us to move forward with repairs.


Matthew B.

Matthew B. Job Checkin

I performed a cooling preventative maintenance. I addressed the concerns of efficiency on the system. I found initially the unit only splitting 18° and the blower setting on medium. I inspect the system and found the indoor coil was not fully seated on the base and allowing unconditioned air to bypass the coil. I remounted the indoor coil and sealed gaps with foil tape. I changed the blower speed back to high and verified gauge readings and temperature split. The house dropped 2° after the changes were made and achieved a 20° split. The unit is operating properly at this time