found the thermostat wasn’t fully installed onto its base. The homeowner had reset the blown breaker. I checked the units operations and it is operating within running amps and the capacitors tested good. The outdoor fan motor case temperature tested OK. The unit is suffering from excessively high starting apms, causing it to trip breaker I recommended inrush kits for both units and maintenance plans to get both units serviced
Performed cooling inspection. While on site during inspection system developed a short do to a bad thermostat. Also took out the contactor. I replaced the thermostat with a customer supplied one and the contactor was covered by us so next warranty per Alex. Once all repairs were done the inspection was completed. The system is cooling upon departure. Preferred Cool Home Membership - 1 System Includes two maintenance visits per year for 1 system Front of the line, priority service over everyone else, guaranteed service within 24 hours Discounted $37 diagnostic fee (versus regular diagnostic fee of $97) 100% of your protection plan goes toward your future system replacement (capped at $1,000) https://www.idealairaz.com/flipbook/cool-home/?page=1
Performed a membership visit and cooling. Homeowners moved forward with recommended repairs and did not have the time for me to perform them need to return and make the repairs. DESCRIPTION Includes two maintenance visits per year - 1 System Front of the line, priority service over everyone else, guaranteed service within 24 hours Discounted $37 diagnostic fee (versus regular diagnostic fee of $97) No weekend or after hour fees 100% of your protection plan goes toward your future system replacement (capped at $1,500) 10% Discount on any repair work needed $200 Discount on Home Performance upgrades https://www.idealairaz.com/flipbook/cool-home/?page=1
Checked system noises Compressor harmonic vibrations Transfers to structure of home System cycles every 6-9 minutes Duct is ok, supply plenum not long enough for proper location of REME Halo Has ODA duct direct from home to roof - no dampers Discussed installing line set vibration isolation Replacing with variable capacity system (Trane or Bosch) Also would like pricing on Mitsubishi multi zone mini split Justin has bad allergies
Bosch heat pump install, insulation installation and removal and replacement, duct sealing in Surprise
DESCRIPTION Preferred Cool Home Membership - 1 System Includes two maintenance visits per year for 1 system Front of the line, priority service over everyone else, guaranteed service within 24 hours Discounted $37 diagnostic fee (versus regular diagnostic fee of $97) 100% of your protection plan goes toward your future system replacement (capped at $1,000) https://www.idealairaz.com/flipbook/cool-home/?page=1
Performed a membership visit in heating. Observed the unit is experiencing excessively high starting amps. Recommend installing and in rush kit to alleviate the stress on the system. The unit unit is experiencing excessively high static pressure in the ductwork and recommend an energy audit.
Full Install of REME HALO®Zero RGF’s proprietary aGHP-Cell™technology creates low level, airborne Gaseous Hydrogen Peroxide (aGHP™) throughout the air-conditioned space Reduces bacteria, viruses, odors, and mold along with allergens & dust at the source. REME HALO®Zero is verified Zero Ozone to UL 2998 https://www.youtube.com/watch?v=1ChdZMrkLeM
Performed a membership visit on the system in heating. The unit is operating properly at this time.
I inspected equipment in heating mode due to low outdoor ambient. Systems both are operating fine at this time. I turned off adaptive intelligent recovery on both systems to prevent them from running at peak usage hours. I recommend installing micro airs on outdoor units to lower start up amps.
Performed a membership visit in heating. Both units are operating properly. The unit over the garage had its insulation in the cabinet fall onto the blower. I glued it back up. The homeowner has allergies and was interested in air purification. I included a proposal for the Reme, zero
I ran a a gas furnace safety start up on Goodman 90% furnace, system operates through its sequence of operations as it should, no gas/co leaks detected on system. Furnace is operating fine at this time. I found refrigerant leak on suction line at aluminum to copper connection.