-Upon arrival I found two leaks by the sillcocks in the house. One at the gate valve shutoff in the bathroom cabinet and one n the frost free section of the hot side sillcock of the outdoor shower. Outdoor shower was also damaged and needed to be replumbed. -Stopped leak under the cabinet by tightening the packing nut. Replaced hot side sillcock and replumbed up to tee on outdoor shower. -Added two check valves on the hot and cold side feeds of the shower to prevent backflow between the hot and cold. -Need to return with adapter from the sillcock into the 1/2” pex. -On second visit tech installed adapter -Upon testing sillcock found that the vacuum breaker with faulty. Return visit with a new vacuum breaker or replacement sillcock may be necessary. -Vacuum breaker was replaced and tested. Vacuum breaker was working well with no leaks present at time of repair.