This was a follow up visit to test the drainage connections within the home since the new septic was completed. The water for the second floor bathroom was turned on and the fixtures were tested. -Tested the kitchen sink faucet to properly test the newly installed cartridge and drainage connections -Tested the first floor lavatory drainage. Noticed a leak on the popup assembly. Tightened the plastic nut to secure the rubber gasket to the bottom of the lavatory. Tested, no leaks. There was no work performed on the popup assembly during this project -Tested the laundry drainage and the water softener drywell drain receptacle by using a washer hose to introduce water to the drains with. -All drainage was tested and no leaks were present. -The exterior drywell drain was not connected by the septic contractors during this visit, so I was unable to place the water softener into service.