Customer needed a 4x20 sediment filter and softener installed. I cut into the existing 1-1/4” copper pipe and installed a ball valve to act as a bypass for the softener and filter. I then plumbed in the sediment filter with a boiler drain and threeway bypass. I installed the sediment filter and back wash drain in the main drain stack. I also added a 3/4” ball valve between the filter and softener as per the customers request. I capped this line to avoid any accidental flooding. I started up the system by bleeding the air out of the media and flushing it. I then set the settings of the system. I set it to 12 grains and a 28 day regen cycle. System is working well with no leaks present at time of service. Customer would like to pay the invoice via email and would like to get on the schedule for a service next year. https://entipur.com/wp-content/uploads/2016/05/Entipur-OwnersManual.pdf