The customer reported moisture in the dryer vent pipe and the carpet in the closet beneath the staircase. Upon arrival an inspection was performed and it was determined there was a leak beneath the slab on the hot water side of the potable water plumbing system. We eliminated the pipes running beneath the slab and rerouted the water line above ground through the wall. The system was tested and no other leaks appeared to be present.