Performed maintenance on 2023 trane 90% furnaces 1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested for gas leaks 6. Tested functionality and cleaned flame sensor 7. Tested functionality and cleaned pressure switches and ports 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Tested functionality and visually inspected surface igniter 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14.Drain line tested with gallon of water for clogs and to push anything trying to solidify out Found no surge protection on the units. This is advised as the coming winter storms could cause power outages and everytime that happens it acts as a power surge on the equipment that could potentially damage expensive electrical components. They protect fro