Today I arrived on site and performed a summer time maintenance on your HVAC equipment. **Indoor Unit (Air Handler in Attic):** * Checked the pleated 20x25x5 filter; it's in fair condition. * Confirmed the indoor coil is clean and in fair condition. **Outdoor Unit (Heat Pump on Side of House):** * Verified the outdoor coil is clean and in fair condition. * Tested and inspected the blower motor, condenser fan motor, compressor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring; all are working properly within manufacturer's specifications. **System Components:** * Inspected the blower wheel, primary drain pan, electrical wires, and ductwork; all are in good condition and working properly. * Cleared the condensate drain line. * Cleaned out the primary pan and tested the safety switch. **Measurements:** * Measured a return air temperature of 72.0 degrees Fahrenheit. * Measured a supply air temperature of 54.0 degrees Fahrenheit. **Add