Today I arrived on site and performed a summer time maintenance on your HVAC equipment. **Indoor Unit (Air Handler):** * Located in the closet, servicing the whole home. * Replaced the pleated 1" air filter (20x25x1) using customer-supplied spare filters. * Confirmed the indoor coil is clean and in fair condition. **Outdoor Unit (Heat Pump):** * Located in the front yard. * Confirmed the outdoor coil is clean and in fair condition. **Electrical Components:** * Tested and confirmed proper operation within manufacturer specifications for: * Blower Motor * Condenser Fan Motor * Compressor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Electrical Wiring **System Components:** * Inspected and confirmed good working condition of: * Blower Wheel * Primary Drain Pan * Electrical Wires Secured **Measurements:** * Return air temperature: 71.0°F. * Supply air temperature: 54.0°F. **Other Actions