Today I arrived on site and performed a summer time maintenance on your HVAC equipment. **Filtration:** * Replaced the pleated 1" filter (18x24x1. 10x10x1) with a spare provided by the customer. **Indoor Unit (Furnace in Closet):** * Confirmed the indoor coil is in good, clean condition. **Outdoor Unit (Straight Cool on Side of House):** * Verified the outdoor coil is in good, clean condition. **Electrical Components (Tested and Working):** * Verified proper operation and amperage of the blower motor, condenser fan motor, compressor, blower run capacitor, compressor run capacitor, electrical wiring, and contactor. **Component Inspection (Good Condition):** * Confirmed the blower wheel, primary drain pan, and electrical wires are secured and in good working order. **System Performance:** * Measured a return air temperature of 79.0°F and a supply air temperature of 52.0°F. * Cleared the condensate drain line. **Additional Actions:** * Wore shoe covers. * T