Today I arrived on site and performed a summer time maintenance on your HVAC equipment. **Indoor Unit (Air Handler in Attic):** * Replaced the 20x20 pleated filter. * Confirmed the indoor coil is clean and in good condition. **Outdoor Unit (Heat Pump on Side of House):** * Verified the outdoor coil is clean and in good condition. * Tested and confirmed proper operation of the blower motor, condenser fan motor, compressor, compressor run capacitor, fan run capacitor, compressor start capacitor, contactor, and electrical wiring. * Inspected and confirmed good condition of the blower wheel, secondary drain pan, primary drain pan, and secured electrical wires. **System Performance:** * Measured a return air temperature of 75.0°F and a supply air temperature of 57.0°F. * Cleared the condensate drain line. * Cleaned out the primary and secondary drain pans. * Tested the safety switch. **Additional Actions:** * Dusted the thermostat. * Restored power to the units