Today I arrived on site and performed a summer time maintenance on your HVAC equipment. **Indoor Unit (Air Handler in Attic):** * Replaced the 20x25x4 pleated filter. * Confirmed the indoor coil is clean and in good condition. **Outdoor Unit (Heat Pump in Back Yard):** * Verified the outdoor coil is clean and in good condition. * Tested and confirmed proper operation of the blower motor, condenser fan motor, compressor, blower run capacitor, compressor run capacitor, contactor, and electrical wiring. * Confirmed the blower wheel, primary drain pan, and electrical wires are secured and in good condition. **System Performance:** * Measured a return air temperature of 76.0°F and a supply air temperature of 54.0°F. * Cleared the condensate drain line, cleaned out the primary pan, and tested the safety switch. * Tested the thermostat operation and restored power to the units. View visual findings from today’s visit here - https://visionshare.xoi.io/?id=msc983c010-cb