Today I arrived on site and performed a summer time maintenance on your HVAC equipment. **Indoor Unit (Furnace in Garage):** * Checked the pleated 20x25 filter (2-6") and confirmed it was in good condition. * Verified the indoor coil was clean and in good condition. **Outdoor Unit (Straight Cool on Side of House):** * Confirmed the outdoor coil was clean and in good condition. * Tested and inspected the blower motor, condenser fan motor, compressor, compressor run capacitor, fan run capacitor, contactor, compressor start capacitor, and electrical wiring; all are working properly within manufacturer's recommended specifications. * Inspected the blower wheel, secondary drain pan, primary drain pan, and secured electrical wires; all are in good condition and working properly. **System Performance:** * Measured a return air temperature of 77.0°F and a supply air temperature of 57.0°F. * Cleared the condensate drain line, cleaned out the primary and secondary pans, and t