403 Headquarters Dr. Unit 5
Millersville, MD 21108
(443) 396-3797

Job Locations
for riviera beach, md


Map of Riviera Beach MD
Larry B.

Larry B.


Job Checkin

Customers powder room on main level receptacle as well as both outdoor outlets are not working. Found a gfci in basement that was working but not sending power to rest of circuit and needed to be replaced. Also the outdoor outlets are not weather resistant and have bad gaskets around them letting water get inside and should also be replaced. Both outside outlets were replaced with weather resistant gfcis and new heavy duty in use cover to be code compliant. Main gfci to left of panel was replaced with a new gfci. The powder room receptacle was just replaced by homeowner and is black in color so it was re installed after re wiring of the device and basement bath was replaced with new gfci. Now anytime one of the gfcis trip at any location only that device will turn off allowing the rest of the circuit to continue being used. Verified proper operation of all completed work with customer.