Unit is a 2017 gas system. It is not communicating or zoned. Blower wheel in need of cleaning. Dirty blower wheels add stress to the motor itself resulting in premature failure. The u/v light had been removed from the system. Customer has a replacement bulb. The bulb was installed in the incorrect location and without a dedicated transformer. This price is the put it on a dedicated transformer in the same location in which it was previously located. The contactor has heavy burning present in the contacts. It is advised to have it replaced. The compressor is start at 75% of its allotted amperage load. It is advised to install a start assist to limit stress on the compressor. The damage to the internals of the compressor are irreversible. I relocated the u/v to above the evaporator coil, and wired in a transformer for the power. I installed a hard start kit to lower the starting amperage. The humidifier is not operational due to the water being shut off. The fitting leaks wh