824 S Central Expressway, Suite 100
Anna, TX 75409
903-482-4900

Job Locations
for trenton, tx


Map of Trenton TX
Brayden W.

Brayden W.


Job Checkin

Arrived on site for heating maintenance 1. Visually inspected condenser coil for debris/ dirty. Very dusty 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. Homeowner replaced filter recently 9. Inspected return plenum for debris/ dirty. Decently dirty 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Inspected drain lines and treated to prevent blockages 15. Rinsed condenser unit to promote heat exchange 16. Replaced and dated filters Found UV light bulb burned out. Discussed duct cleaning and replacing uv bulb to keep system keep and prolong life of the system. Homeowner declined at this time, but would like to discuss the

Arrived on site for heating maintenance 
1. Visually inspected condenser coil for debris/ dirty. Very dusty
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested compressor/ condenser fan motor capacitor.
6. Checked compressor amp draw.
7. Checked condenser fan motor amp draw.
8. Inspected / replaced return filter. Homeowner replaced filter recently
9. Inspected return plenum for debris/ dirty. Decently dirty
10. Inspected evaporator coil.
11. Inspected blower motor/ blower wheel.
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14. Inspected drain lines and treated to prevent blockages 
15. Rinsed condenser unit to promote heat exchange
16. Replaced and dated filters

Found UV light bulb burned out. Discussed duct cleaning and replacing uv bulb to keep system keep and prolong life of the system. Homeowner declined at this time, but would like to discuss the Arrived on site for heating maintenance 
1. Visually inspected condenser coil for debris/ dirty. Very dusty
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested compressor/ condenser fan motor capacitor.
6. Checked compressor amp draw.
7. Checked condenser fan motor amp draw.
8. Inspected / replaced return filter. Homeowner replaced filter recently
9. Inspected return plenum for debris/ dirty. Decently dirty
10. Inspected evaporator coil.
11. Inspected blower motor/ blower wheel.
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14. Inspected drain lines and treated to prevent blockages 
15. Rinsed condenser unit to promote heat exchange
16. Replaced and dated filters

Found UV light bulb burned out. Discussed duct cleaning and replacing uv bulb to keep system keep and prolong life of the system. Homeowner declined at this time, but would like to discuss the