Compressor Replacement R-410a under manufacturer's limited parts warranty Remove old compressor & filter drier while purging Nitrogen to prevent contamination Install new OEM compressor and filter drier Purge W/ Nitrogen while brazing to prevent contamination Pressure test entire system with Nitrogen to 500 PSI to ensure system is leak free Triple Evacuate system with digital micron gauge to below 250 Microns Re-charge system with new R-410a refrigerant to manufacturer's specifications Non Members: 90 day parts + labor warranty on all repairs Cool home members: 2 year parts + labor warranty on all repairs R- 410a Adjust Refrigerant level: Every pound after 1st RECOMMEND LEAK SEARCH BEFORE ADJUSTING REFRIGERANT CHARGE Purge gauges to ensure no non-condensables enter system Use digital scale to weigh in refrigerant Adjust according to units TP chart and super heat and sub cool