Charles B.

Charles B. Job Checkin

Arrived to home Checked thermostat Checked system Found head pressure excessively high Exit temp on condenser approaching 150 degrees Damaging fan motor Compressor bypassed while on site Cooled compressor Restarted system Explained due to incorrect fan motor condenser was only able to exhaust approximately 50% of heated air This caused recirculating of condenser air and damaging of compressor and fan motor

Arrived to home
Checked thermostat
Checked system
Found head pressure excessively high
Exit temp on condenser approaching 150 degrees 
Damaging fan motor
Compressor bypassed while on site
Cooled compressor
Restarted system
Explained due to incorrect fan motor condenser was only able to exhaust approximately 50% of heated air
This caused recirculating of condenser air and damaging of compressor and fan motor

Charles B.

Charles B. Job Checkin

Arrived to home Checked thermostat Checked system Found line wires melted at Contactor Inrush kit failed Comp cap failed CFM cap failed Incorrect fan grille and fan motor installed Evap coil severely rusted Indoor section dirty Temporary repairs Inrush kit Contactor CFM cap Compressor cap Cleaned condenser coil **due to age and severe deterioration highly recommend replacement soon

Arrived to home
Checked thermostat
Checked system
Found line wires melted at Contactor
Inrush kit failed
Comp cap failed
CFM cap failed
Incorrect fan grille and fan motor installed
Evap coil severely rusted
Indoor section dirty


Temporary repairs
Inrush kit
Contactor
CFM cap
Compressor cap
Cleaned condenser coil

**due to age and severe deterioration highly recommend replacement soon