Replace Condenser Coil: Part under warranty Remove leaky damaged coil and pump down refrigerant into out door unit Install new OEM coil + filter drier and purge with Nitrogen while brazing Complete leak test with Nitrogen to 500 PSI Evacuate system to below 500 Microns Check charge and add refrigerant as needed. If R-22 system add refrigerant charge Record super heat, subcool and temperature split Non Members: 90 day parts + labor warranty on all repairs Cool home members: 2 year parts + labor warranty on all repairs