Arrived to home Checked thermostat Checked system Found head pressure excessively high Exit temp on condenser approaching 150 degrees Damaging fan motor Compressor bypassed while on site Cooled compressor Restarted system Explained due to incorrect fan motor condenser was only able to exhaust approximately 50% of heated air This caused recirculating of condenser air and damaging of compressor and fan motor

Arrived to home
Checked thermostat
Checked system
Found head pressure excessively high
Exit temp on condenser approaching 150 degrees 
Damaging fan motor
Compressor bypassed while on site
Cooled compressor
Restarted system
Explained due to incorrect fan motor condenser was only able to exhaust approximately 50% of heated air
This caused recirculating of condenser air and damaging of compressor and fan motor