Arrived on site to replace hyvent and electrode assembly. Upon arrival we turned off power and removed old electrodes. Removed the old gasket as well. We then installed new gasket and electrodes. We then drained the zone with the hyvent we were replacing. Installed and dated new hyvent. Refilled zone and purged of air. All zones are heating properly. Thank you for your business!