The reason for today’s visit was to provide a solution for customer to install lighting located in the living room, second floor hallway, and both bedrooms on the second floor. While here assessing the panel, i saw a 00’ Square D Homeline panel with many signs of concerns. There were double tapped neutrals, shared neutral circuits, and missing grounding. While checking the service cable i saw the outer jacket was completely ripped open exposing neutrals and feeder wires. I provided a solution for the customer on replacement of this and bringing it up to date with current safety requirements. After viewing the panel, i began providing a solution for four six inch gimbal recessed lights in the living room. Currently customer has a switch controlled outlet and we would turn that into a dimmer for the recessed lights. The second floor housed three fixtures and customer would like to have those replaced with three recessed lights as well in exact location. In two of the bedrooms on the seco