We arrived today to provide estimate for tanked to tankless water heater conversion. The tankless natural gas water heater must be installed a minimum of 4 feet away from any operable window, door, or any source of ignition, in compliance with local code and manufacturer specifications. Proper exterior wall space must be confirmed to accommodate unit clearances, venting, and mounting hardware. Gas Line Installation: A new natural gas line will be routed from the existing gas meter to the tankless water heater's location. Gas sizing calculations will be performed to ensure adequate supply based on the unit's BTU rating and other gas appliances in the home. Electrical Requirements: The tankless water heater will require a dedicated 120V GFCI-protected electrical outlet at the unit’s location for operation. Electrical work will be coordinated to ensure code compliance and proper grounding. Water Line Modifications: Existing hot and cold water lines from the current electric tank system