Performed cooling maintenance and dryer vent cleaning as scheduled 2. Visually inspected condenser coil for debris/ dirty. 3. Inspected condenser fan motor. 4. Inspected condenser fan blades. 5. Inspected/ cleaned wiring connections. 6. Tested compressor/ condenser fan motor capacitor. 7. Checked compressor amp draw. 8. Checked condenser fan motor amp draw. 9. Inspected / replaced return filter. 10. Inspected return plenum for debris/ dirty. 11. Inspected evaporator coil. 12. Inspected blower motor/ blower wheel. 13. Checked blower amp draw. 14. Measured temperature differential from supply to return. 20 degrees measured. 15. Inspected drain lines and treated to prevent blockages 16. Rinsed condenser unit to promote heat exchange Found 5 year old capacitor on outdoor unit testing within range. Typical life span of capacitors is about 3-5 years and unit will not work without it and may cause damage if allowed to continuously attempt to run in cooling. Found fresh air intake filter ex