- Provided courtesy call to homeowner to confirm appointment time and verify address. - Met homeowner/Blake… he explained his issue with upstairs thermostat and that it will cool to 75°F but when they adjust it to 74 it can never reach 74°F. - Provided a demand for cooling at thermostat. - 20x25x4 Air Filter is clean and pointed correctly - System draining properly and not retaining water. - no air restrictions in air distribution assembly -System needs maintenance…outdoor condenser coils need cleaning. - checked all electrical components/amp draws - refrigerant charge is within manufacturer operating specifications. - system providing a 17.8+°F temperature drop across the coil - photo documentation attached - thermostat displays correct temperature. - AC diagnostics checklist form filled out and attached. - System cooling, draining, communicating/functioning properly and within manufacture specifications upon departure. - technician cannot find any issues affecting performance ot