Job Checkin

Performed AC maintenance on 2000 ICP Condenser. Upon my maintenance there were a few points of concerns there we’re noticed 1. Outdoor Condenser fan motor has significant oil leakage coming from Bearing and can potentially lead to motor locking up overheating 2. Duel secondary motor control is weak on hermetic side terminal 3. High voltage distributor had an ant build up on contact points. This can lead to contact point having an imperfect connection which results in the system not turning on 4. System Contained R22 refrigerant which was completely phased out on January 1, 2020 5. System Has major air Restrictions which resulted in very low superheat reading on my refrigerant gages. This is resulting in colder temperatures inside the evaporator coil which will cause a suction line to ice up overtime 6. Filter needs to be swapped every one to three months Will be sending over maintenance information due to homeowner not being here at the property. Upon departure system is fully opera