Jimmy P.

Jimmy P.


Job Checkin

Performed Furnace diagnostic on 1985 RUUD heater. Upon arrival homeowner stated that the system was just maintained about a year ago and was told everything was OK. Now it appears at the system is working intermittently but they only really use it in the morning but the last two days it was nonfunctional. Began my troubleshooting and conducted a safety inspection on the furnace and found many points of concerns. 1. Furnace had shut down after about five minutes and found that filter inside of indoor blower cabinet was really blocked up with With Dust and debris due to it being a washable filter it needs to be cleaned out every month 2. Spark ignition box appears to not be sending power to spark igniter. Although does at certain times. 3. Indoor blower motor has oil leakage coming from its bearing and will lead to it locking up or overheating. 4. Airflow was measured on Furnace and found that it was 0.88 WC total which is heavily restricted for a furnace 5. Gas line also was directly r