Job Checkin

Customer stated: navien is leaking gas Technician notes: upon inspection found that middle navien gas valve is where the leak is coming from. Recommend: gas valve needs replaced. Parts: spoke with Robert about correct parts that need ordered. MGP notes: customer stated that he was driving and will call office with payment when he stops. Job status: not complete, will need to order part and return to complete job once payment is received. This is a service estimate to replace the gas valve in the middle navien. 6/24/24 Technician notes: out today to replace gas valve on navien tankless unit. Gas to the tankless is already turned off and the front cover is removed already. Removed old gas valve from tankless unit and installed new navien gas valve. Turned gas on and opened all shut off valves, turned tankless on and began testing it by letting in kick on and off multiple times. Tankless unit is working properly at this time. There is a faint smell of gas at this moment but the