41638 Eastman Dr. Suite B
Murrieta, CA 92562
(888) 659-2665

Local Reviews
for aguanga, ca

Rated 4.4 out of 5 stars based on 5 customer reviews

Excellent service

Jared was extremely friendly and professional.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent!

Shane forget the connect air conditioner so Luiz found it connect ! Thank you !

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent!

Shane is explain us that he know little sign language so nice guy ! Thank you !

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service/ very friendly & very informative

He was professional and polite

  • Overall Experience
  • Quality
  • Price
  • Convenience

extremely knowledgeable and informative

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for aguanga, ca

Jared F.

Jared F. Job Checkin

Performed a furnace maintenance on a Vexar system. Checked performance, temperature split, and blower condition.

Performed a furnace maintenance on a Vexar system. Checked performance, temperature split, and blower condition.

Alex R.

Alex R. Job Checkin

Ac maintenance


Evan V.

Evan V. Job Checkin

Performed a hearing maintenance on a revolv system. Cleaned and Adjust Burners. Check Combustion Air for Proper Venting. Examine the Heat Exchanger for Damage / Corrosion. Test Furnace Safety Controls. Inspect Gas Piping. Tighten Electrical Connections. Measure the Voltage and Amperage. Flush the Condensate Drains. Measure Tempurature Difference between Supply and Return Air. Vacuum Furnace Return Grille. Adjust Gas Pressure & Pilot. Clean in-place Blower Compartment. Inspect Blower Wheel for Proper Balance. Check the System's Static Pressures to Ensure Proper Airflow. Inspect Duct Connections for Air Leaks / Sizing / Insulation. Check all System Safety and Limit Switches. Clean Flame Sensor. Inspect Carbon Monoxide Detector. Check Thermostat for Proper Operation / Calibration. Filters where changed this visit. System was fully operational on time of departure.


Travis R.

Travis R. Job Checkin

Performed a heating maintenance on a 2021 Lennox system. Cleaned and Adjust Burners. Check Combustion Air for Proper Venting. Examine the Heat Exchanger for Damage / Corrosion. Test Furnace Safety Controls. Inspect Gas Piping. Tighten Electrical Connections. Measure the Voltage and Amperage. Flush the Condensate Drains. Measure Tempurature Difference between Supply and Return Air. Vacuum Furnace Return Grille. Adjust Gas Pressure & Pilot. Clean in-place Blower Compartment. Inspect Blower Wheel for Proper Balance. Check the System's Static Pressures to Ensure Proper Airflow. Inspect Duct Connections for Air Leaks / Sizing / Insulation. Check all System Safety and Limit Switches. Clean Flame Sensor. Inspect Carbon Monoxide Detector. Check Thermostat for Proper Operation / Calibration. Filters where not changed this visit. System was fully operational at time of departure.


Jimmy P.

Jimmy P. Job Checkin

Arrived on site to perform furnace/heatpump maintenance


Tony R.

Tony R. Job Checkin

During my 20 point inspection, I Started off with hosing down condenser coil of any dirt and debris. Cleaned under compressor as well. Opened condenser cabinet and checked everything thoroughly. Starter (good), fuses (good), motherboard (good), dual secondary motor control (good), 24v (good), 120v (good), refrigerant levels sh 4, sc 2, osa 81, delta 29. Then went onto the furnace and checked furnace cabinet thoroughly. Blower motor (good), single secondary motor control (good), motherboard (good), 24v (good), 120v (good). House cools great and ready for summer.


Jimmy P.

Jimmy P. Job Checkin

Performed heatpump maintenance on one year-old Lennox. Maintenance checked out properly and surge protector was installed and registered. System was reset and tested upon departure.


Michael P.

Michael P. Job Checkin

Replaced two high limit switches on the furnace. Adjusted zoning supply temp perimeters. Monitored operation and ignition cycle. Measured supply temperatures and ensured system reached target set point.


Michael P.

Michael P. Job Checkin

Made airflow adjustments. Adjusted cfm zone settings, bled dampers. Added furnace condensate trap, measured gas valve pressure. Monitored operation.


Michael P.

Michael P. Job Checkin

Performed maintenance on ICP heating unit. Wiped down furnace with wet rag. Tested controls and measured ignitor. Measured electrical values and amp draws. Removed insulation foam and replaced with metal tape to reduce lost airflow at the evaporator coil lineset plate. Replaced 1” filters. Measured temperature rise. *cannot access ignitor / flame sensor due to bolt behind gas valve*


Daniel T.

Daniel T. Job Checkin

Upon arrival customer reports heating has been used often until this morning. Error code 38 and 223 were present. Heat pump mode works fine. Auxiliary heat was not kicking on. Found a moles plug was disconnected. System is operational at this time. Indoor protection and a filter were installed today.


Darren F.

Darren F. Job Checkin

Job walk


Freddy V.

Freddy V. Job Checkin

Collected a deposit of 3445 by check. Balance due will be 31005 due upon completion


Michael P.

Michael P. Job Checkin

Removed defective flare from the copper lineset and refitted connection with new flare. Used nylog thread sealant and tightened bolt. Pressurized system with 200 psi of nitrogen and leak tested connection with soap bubbles. Vacuumed system down to below 500 microns. Weighed in refrigerant charge with digital scale (3.10lbs) r410a. Tested system and measured indoor temps. Soap bubbles connection again, system is working properly at this time.


Luis M.

Luis M. Job Checkin

Replcad cap under warranty. Fan was not spinning