David J.

David J. Job Checkin

Performed 1 heat pump system maintenance. Replaced 1-18x20x1 filter. Damper for upstairs zone not working properly, found broken wire going to damper, was not getting low voltage power to close damper when needed. Fixed broken wire and system is now operating properly.


Jordan E.

Jordan E. Job Checkin

Warranty- thermostat was set to fan in the on position. Customer said it happened at our prior visit. Set fan to auto mode and cycled the thermostat to confirm proper function. I explained the thermostat fan settings to the customer.


Jordan E.

Jordan E. Job Checkin

Replaced damper motor for upstairs under for parts and labor warranty


Michael  J.

Michael J. Job Checkin

Found popped three amp fuse in the air handler located in the attic, caused by shorted contactor in the outdoor unit. Installed new single pole contactor. Replaced low-voltage fuse. System is now cooling..


Jordan E.

Jordan E. Job Checkin

I performed a one system maintenance on a heat pump in the attic. I looked over all the low-voltage change The filter, looked over the blower motor blew out the drain line entry to the drain line. I checked the charge. The capacitor and washed outdoor system. The System is running and operating like I supposed to. The upstairs damper motor is sticking close got it to open. Will need to return and replace it.


Jordan E.

Jordan E. Job Checkin

Keven dispatched to the wrong call.


Jeremy  P.

Jeremy P. Job Checkin

I performed a heating maintenance on a single heat pump air handler unit I replaced the 18x20x1 filter I checked all electrical components and checked the temp rise and checked the Freon levels and checked the capacitor everything is in good working order at this time.


Jeremy  P.

Jeremy P. Job Checkin

Maintenance/tune up completed in Morrow Ga


Jeremy  P.

Jeremy P. Job Checkin

I performed a cooling maintenance on a single heat pump air handler I replaced the 18x20x1 filter I checked all electrical components and checked the temp drop and cleaned the drain line and I checked the Freon levels and checked the capacitor everything is in good working order at this time. Today is a renewal payment of 176.00$.


Joseph R.

Joseph R. Job Checkin

Upon arrival, found water spots in the master bedroom ceiling. In the attic, found water intrusion signs in the insulation above the water spots in the master bedroom ceiling. Found a roof vent directly above the water spots in the insulation. Inspected ductwork going back to the master bedroom and the duct is sealed and not leaking. Inspected the air handler and the air handler is showing no signs of leaking as well. The most likely cause of the leak is due to roof leakage.


Chris B.

Chris B. Job Checkin

Inspected furnace and found problematic gas line. Turned gas off and fixed gas line by installing a gas ball valve and sediment trap. Turned gas back on and tested system. Furnace system is operating properly at this time.


Chris B.

Chris B. Job Checkin

Quote hvac


David J.

David J. Job Checkin

Replaced bad damper motor.