Daniel B.

Daniel B.


Job Checkin

2023 Fall Check Up PCSA Prepaid Checked wire connections. Replaced filter. Heat strips are operating normally. Puron levels are within range. Thermostat is operating normally. Checked defrost mode on outdoor coil. Ambient sensor appears to have failed which will prevent the system from going into defrost mode when needed. Recommend replacement when possible.