Lennox mini split was installed by another contractor, drain line was not installed properly and came apart causing all condensation to leak down and through insulation and ceiling, with the right material we can fix drain but recommended to customer to have original contractor fix their mistake/oversight. Things that will need addressed are: -PVC pipe taped to mini split drain -sagging PVC pipe -lack of support brackets for PVC pipe If we come back to fix drain, will need to bring drain hose small enough to fit inside 3/4 PVC