Tenant reported ac not running inspected electrical component’s and found no power on bottom side of disconnect breaker inside of air handler. A temporary fix was performed to get system running. Auxiliary heat kit will need to be ordered. Will send estimates for parts and labor on 6/26/23. Once system was running refrigerant charge was checked and system is approximately 3 pounds low on refrigerant signaling a possible leak will need to add refrigerant for optimal cooling. Also auxiliary heat was disconnected do to a possible short in the auxiliary heat circuit causing them to be on when system is calling for cooling. Due to age condition and amount of mold present in air handler system replacement is recommended.