824 S Central Expressway, Suite 100
Anna, TX 75409
903-482-4900

Job Locations
for mckinney, tx


Map of McKinney TX
Cesar  O.

Cesar O.


Job Checkin

Performed a 1 system spring maintenance ( gas). Tasks performed. 1. Visually inspected condenser coil for debris/ dirty,,,recommended a surge protector this would protect the outdoor unit from over current to. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor,,,recommended a hard start kit this extends the life on the compressor and releases stress at start up. 6. Checked refrigerant pressures. 7. Checked compressor amp draw. 8. Checked condenser fan motor amp draw. 9. Inspected / replaced return filter. 10. Inspected return plenum for debris/ dirty. 11. Inspected evaporator coil. 12. Inspected blower motor/ blower wheel,,,both are dusty highly recommended a blower cleaning,, this prevent buildup on the blower wheel then unbalance. 13. Checked blower amp draw. 14. Measured temperature differential . 15. Inspected drain lines. 16. Washed condenser unit. Unit is cooling prope