Performed AC Diagnostic and comfortmaker Unit. Upon arrival client stated that the system has been working properly But has recently noticed that the secondary drain line on the side of the house has been draining out a lot. They have no prior information on how the system looked or what the condition of it is in at the moment nor did inspector say anything about the unit. During the diagnostic I found multiple points or concerns that were addressed with the homeowner. Primary drain line was heavily clogged and homeowner cleared out P-trap under sink. Return duct is Pretty much disconnected from the top of the heater which can result in a lot more condensation and higher energy bills. System is also heavily caked in dust and debris. Evaporator Coil has no secondary drain pan underneath and also has shown signs of prior flooding in the attic. The system is at a very high risk of leaking and also has no secondary float switch. Client does not want to sign up on maintenance plan at the mo