Performed diagnostic on 4 year old Maytag furnace. It was installed by Synergy. System is not heating. Only blows cool air in heat mode. Cycled system for heat. System kicks on and inducer started blowing, but then cut off after about 1 minute. Blower wheel kicks on afterward and just blows air. After several troubleshooting cycles, figured out that the circuit board is cutting power to the inducer, even though the thermostat is still calling for heat and board is still recieving command. Circuit board needs to be replaced. Looked up warranty for unit online through Maytag and circuit board is out of warranty. Or homeowner know and showed her online paperwork. Went over recommendations. Signed homeowner up on monthly maintenance program. Need to order circuit board and return to install. System is not operational upon departure.