725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Job Locations
for dublin, oh


Map of Dublin OH
Graham M.

Graham M.


Job Checkin

Gas heating preventative maintenance performed Check filter - 20x25x4 ok 8/25 Clean flame sensor Ohm test igniter: 47.6 Inspect wiring for loose connections and/or hot spots - Check humidifier pad: ok #35 Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 3.2 Check amp draw on inducer motor:1.2 Check delta T - 48° Furnace is in optimal running conditions

Gas heating preventative maintenance performed
Check filter - 20x25x4 ok 8/25
Clean flame sensor
Ohm test igniter: 47.6
Inspect wiring for loose connections and/or hot spots - 
Check humidifier pad: ok #35
Inspect exhaust flu - no concerns 
Set thermostat for heat
Check amp draw on blower motor: 3.2
Check amp draw on inducer motor:1.2
Check delta T -  48°
Furnace is in optimal running conditions