Great Service

Seth is very kind and reliable. He tells what he is going to do, then does it in the time specified. He makes honest evaluations of the equipment.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Quick, super helpful

Quick turn around, great price for what I needed done. Very happy, my house is warm again.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Knowledgable and Fast Response

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for hilliard, oh

Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 16x25x4 new today owner supply Clean flame sensor Ohm test igniter: 63.2 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: new today owner supply Inspect exhaust flu - 2” pvc no concerns Set thermostat for heat Check amp draw on blower motor: 2.32 Check amp draw on inducer motor:0.65 Check delta T - 54° Furnace is in optimal running conditions


Nate G.

Nate G. Job Checkin

Diagnosed failed hot surface igniter. Lit furnace manually, ran combustion test. Heat exchanger failed: rise in O2 and CO with blower startup. Tested supply air, 0ppm CO. Discussed diagnosis and explained furnace needs replaced. Agreed to new igniter to keep it running until we can get our replacement team out here.


Nate G.

Nate G. Job Checkin

Diagnosed failed nest thermostat. Checked thermostat wire sheathing... only brown is degraded and is unused. Explained how to wire the humidifier to the new thermostat. Also discussed maintenance plans.


Nate G.

Nate G. Job Checkin

Performed heating maintenance on a Tempstar 80% efficient two stage natural gas furnace. Replaced air filter Pulled and cleaned flame sensor Verified control board setup switches for airflow settings and adaptive two stage operation with a single stage thermostat Gas pressure for high fire set to 3.2" and has a 48 degree temperature rise. Gas pressure for low fire set to 1.6" and has a 43 degree temperature rise. Ran furnace for an extended period to be sure no high temperature limit trips. All electrical components test within manufacturer's tolerances Wiring is all tight and secure, no visual signs of overheating or fraying. No carbon monoxide detected in supply or return ductwork Blower wheel is clean and free of any debris


Nate G.

Nate G. Job Checkin

Customer concern was noise at startup and shutdown of the heat and more noise from the second floor return during operation. Increased set point to initiate a call for heat. The audible click of the humidifier water solenoid valve could clearly be heard throughout the hoise. The noise from the second floor return was the fan of the humidifier transmitting noise through the ductwork. Cycled humidifier on and off while customer stood under the return grille. He verified the noise was the humidifier and asked it be shut off. Explained the benefits of the humidifier and the maintenance requirements for it. He said his small child is scared of the noise and wishes to not use it as a result.


Nate G.

Nate G. Job Checkin

Furnace was operating upon arrival. Only one stored fault code present, it was E2.1... ignition proving failure. Pulled and cleaned burners. They were rusty and not allowing reliable crossover ignition. Pulled and cleaned the flame sensor, too. Quoted stainless steel burners.


seth p.

seth p. Job Checkin

2015 Lennox 80 Plus upflow basement install gas furnace Upon arrival today the system was at the set temperature and heating mode with the blower running. Heating appears to cycle on and off normal and is running at 134° in the supply plenum Homeowners complaint of furnace fan motor never turning off appears to have been resolved by resetting the thermostat fan mode to auto instead of on. Suspect children in the house inadvertently change the setting. Run test Lenox healthy climate powered 700 series humidifier and set to 35%, resurface flame sensor, run test heat mode Replace 16x25x1 pleated air filter from truck stock


Jeramie T.

Jeramie T. Job Checkin

Performed heating pmi checked electrical OK checked and replaced 20x25x4 filter and replaced water panel with owners cleaned flame sensor and checked ignitor blew out drain lines and drain trap cycled system in heating checked motor amps and temperature rise furnace operating properly at this time


seth p.

seth p. Job Checkin

Two system water furnace 5 series heating equipment tune up, maintenance, cleaning, filter inspection, safety inspection Upon arrival and initial test runs both system antifreeze ground loops are registering 0 PSI. Neither system has recorded any major service codes that need attention. In 4 years time between both systems one unit had one communication service code both units had two over under voltage codes and 15 to 20 system resets. Repressurize both ground loops to 45 PSI, maximum household water pressure. Shop vac all equipment and blowout condensate drain traps, Run test all equipment in multi-stage heat pump heating mode and all stages of auxiliary heat. The three ton system is running an excellent condition within parameters in all aspects. April Air 700 humidifier had the water turned off but is functioning correctly at this time. Humidifier began to drip out of the bottom after 5 minute run test. After repositioning of the evaporator pad and drain tray the system no lon


Graham M.

Graham M. Job Checkin

Furnace maintenance inspection performed 5967 Inspect filter:17.5x27x5 Inspect burners: clean Ohm ignitor:54.7 Clean flame sensor Inducer amps: 0.71 Blower Motor amps: 3.28 All wiring OK Humidifier: n/a Temperature rise: 47⁰ Furnace is running in optimum condition. Furnace maintenance inspection performed 5959 Inspect filter:17.5x27x5 Inspect burners: Clean Ohm ignitor: 55.7 Clean flame sensor Inducer amps: 0.68 Blower Motor amps: 3.50 All wiring OK Humidifier: n/a Temperature rise: 48⁰ Furnace is running in optimum condition.


Jeramie T.

Jeramie T. Job Checkin

Install new Daikin FIT HVAC system Furnace: DM96VC0603BNA AC: DX6VSS3010A Coil: CAPEA3026B4A Daikin One communicating thermostat: DTST-TOU-A NuShield Air Purifier * Reconnect to existing gas line and high voltage electric * Transition to existing supply and return ductwork * Start up and commission new system 12 Year Daikin manufacturers parts warranty (Annual maintenance must be performed) 2 Year Westin Air labor warranty (Annual maintenance must be performed) Lifetime Heat Exchanger Warranty (Annual maintenance must be performed)


Nate G.

Nate G. Job Checkin

16 SEER Trane AC system maintenance check.

16 SEER Trane AC system maintenance check.

Nate G.

Nate G. Job Checkin

AC checkup

AC checkup

Nate G.

Nate G. Job Checkin

AC checkup

AC checkup

Wes  S.

Wes S. Job Checkin

Daikin ductless heat pump installation.

Daikin ductless heat pump installation.