Westin Air continues to exceed my expectations for responsiveness and quality of service! Everyone is extremely friendly, understand and accommodating to help make the situation right! I would highly recommend Westin Air to anyone who wants a reliable, friendly and HONEST HVAC company!!
Overall Experience
Quality
Price
Convenience
Great experience! Everyone was so nice from scheduling to the technician. Prompt and helpful. Overall an excellent experience and I will recommend them to other!
Overall Experience
Quality
Price
Convenience
I have known Seth from Westin Air for 4 years and must say he NEVER disappoints! I have complete faith and trust in him that he is taking the best approach to fix my a/c! I highly recommend Westin Air!
Overall Experience
Quality
Price
Convenience
Called Westin Air for a “bum” furnace on a Monday morning and a tech was there Monday afternoon. Quick assessed the situation, identified the issue and promptly fixed. Would recommend.
Overall Experience
Quality
Price
Convenience
Worked with Seth today and covered all of needs for my services. I have worked with Westin before and would give high five!!
Overall Experience
Quality
Price
Convenience
Seth, is does a great job with the service and explaining his service. He is very pleasant and knowledgable re the heating and airconditioning system.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
The service we received was great. Everything that was done was a nice clean job. The price was satisfactory. I apologize for taking so long to respond. I just have a hard time with filling things out. so, sorry again
Overall Experience
Quality
Price
Convenience
Gave tutorial on operating the stats Locked zone panel into emergency heat to only use the gas furnace She's happy now
Performed 3 system heating maintenance Main floor: 2014 Lennox 98% efficient modulating natural gas furnace Honeywell popup 2400 air filter is clean Blower wheel is clean Humidifier has wrong size water panel installed, recommend using aprilaire #35 water panel. Pulled and cleaned the flame sensor Cleared debris from the intake pipe Cleared debris from the inducer outlet drain tubing Lennox does not recommend adjustments to the modulating gas control valve Bonus room: 2000 Lennox 90% efficient single stage furnace Honeywell popup 2200 is clean Blower wheel is OK No humidifier installed Pulled and cleaned flame sensor Condensate lines are clear Intake clear Run tested furnace while running combustion analysis Gas pressure 3.8"wc with reference to the sealed burner box Combustion results are very healthy Temperature rise 50⁰ (spec 30-60) Despite age, this furnace is running well within manufacturer's specs Second floor: 2018 Trane 96% two stage Popup 2200 filter is good Blower wh
Gas heating preventative maintenance performed Check filter - 20x25x4 new today Clean flame sensor Ohm test igniter: 62.7 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: new today #35 Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 3.2 Check amp draw on inducer motor:0.98 Check delta T - 57° Furnace is in optimal running conditions Gas heating preventative maintenance performed Check filter - 16x25x4 new today Clean flame sensor Ohm test igniter: 56.4 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - 2” pvc Set thermostat for heat Check amp draw on blower motor: 3.10 Check amp draw on inducer motor:0.23 Check delta T - 52° Furnace is in optimal running conditions
Performed heating maintenance on a Trane 80% efficient single stage natural gas furnace Replaced 14x25x1 filter Pulled flame sensor and cleaned Cleared pressure switch port Blower wheel is in OK condition Run tested furnace Gas pressure 3.5"wc Temp rise 56⁰
Remove and replace seized inducer motor with factory replacement and test run system, homeowner requested Reprogram thermostat for touch calibration, pull and clean burners due to rust. After inducer replacement inspected gas valve and found valve won’t open. Check for power valve getting power, check pressure no pressure on power sequence. Valve needs replaced as well. Install universal gas valve and test run furnace had to covert 3 wire plug for proper operation. No issues after repairs were made, set gas to 1.5 low 3.2.
Performed maintenance Cleaned flame sensor Filter is new Blower is clean Drain is clear Temperature rise 54⁰ Low fire gas 1.65 High fire gas 3.35 Combustion test was OK. 12%O2 15ppm CO
Gas heating preventative maintenance performed Check filter - 14x25x1 Clean flame sensor Ohm test igniter: 56.1 Inspect wiring for loose connections and/or hot spots - none found Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 4.29 Check amp draw on inducer motor:0.76 Check delta T - 55° Furnace is in optimal running conditions
SOLD: 10/14/2025 9:25:43 AM - Option 1 Install New Bryant Two Stage Gas Furnace Model #: 926TC60100V21 Serial #: 2425A48361 100,000 BTU’s - 96% AFUE Installation: * Reconnect to existing gas line and high voltage electric * Transition to existing supply and return ductwork * Start up and commission new system * Honeywell T10 Smart Thermostat * AprilAire Model 5000 Air Filter Warranty: 20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed) 10 Year Bryant manufacturers Parts Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed)
Performed heating maintenance on a 2003 Bryant single stage 90% efficient natural gas furnace Pulled condensate trap and flushed with water Pulled and cleaned flame sensor 16x25x1 is in shape Blower in OK condition Run tested furnace Performed combustion test: readings are still in a fantastic operating range Gas pressure 3.2 Temp rise 65⁰ Despite age, furnace is still operating well within factory specifications
Performed heating maintenance on a 2017 Bryant 80% efficient single stage natural gas furnace 20x25x4 filter is still OK Aprilaire #35 humidifier water panel is OK Humidifier bypass damper is open to the winter setting Set humidistat to 35% relative humidity Pulled and cleaned furnace flame sensor Blower wheel is clean Run tested furnace Gas pressure 3.8 Temperature rise in spec Ran combustion test: results are within acceptable range Furnace is in good shape and operating within manufacturer's specifications at this time
Upon arrival inspected furnace and found unit on code 3.4 pressure switch error. inducer motor was not operating. Extremely hot to the touch, replacement motor required due to seized bearings to start furnace up. Quote presented and part ordered customer approved.
Preventative maintenence inspection on two gas furnaces and one electric air handler. All air filters are incgood condition. Gas furnaces cleaned flame sensors and checked ignitors. Visual inspection of burners. Flush condensation traps and drain lines. Run test units in gas heating modes. All operating specifications are met properly. Electric air handler electric strip heat and heat pump heating test. All equipment is operating properly, efficiently and ready for Winter.
2021 Bosch high efficiency furnace running in great condition. 24x25x4 air filter is in new condition Filter included with Platinum heating maintenance will need to be special ordered as it is not a common stock size filter. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Humidifier pad in good condition, damper opened, run test during heating mode. Run test furnace in first and second stage heating Both stages running properly within temperature rise specifications. Inducer motor and blower motor are operating within specifications. Furnace is operating properly, efficiently and ready for Winter
Two system heating maintenance Basement furnace 21yr old Trane 80% efficient single stage natural gas furnace Pulled and cleaned flame sensor Changed 20x25x4 filter Blower in OK condition Capacitor tested 15.2mfd (rating 15) Gas pressure 3.5 0ppm carbon monoxide present in supply duct during operation Combustion test well within nominal ranges for a healthy heat exchanger Temperature rise 38⁰ (35-65 rating) Made sure pressure switch port free of soot buildup No concerns found with this Furnace 2nd floor furnace 4yr old Trane 80% efficient single stage natural gas furnace Pulled and cleaned flame sensor Changed 16x25x1 filter Blower clean Gas pressure 3.5 0ppm carbon monoxide in ductwork or around the furnace Temperature rise 44⁰ (30-60 rating) Made sure pressure switch port is free of soot buildup No concerns found
Diagnosed mini split System is definitely not cooling properly. Heat mode works but still not where it should be in the current temperatures. Recommend replacement