Three system Waterfurnace geothermal 5 series package systems 2 alcohol ground loops pressurized with three flow centers, repressurized both to 65 PSI Inspected and reinstalled all existing air filters dated in January Clean and flush all drain systems and minor maintenance cleaning of all systems System B had 25 FP1 service codes But is running in excellent condition today. Suspect lower than desirable ground loop antifreeze pressure All equipment is running in very good condition and ready for summer
Upon arrival the system was in FP1 lockout and retry mode with 420 logged FP1 short cycles. Last visit to this house was Seth replacing the ABC board in November 2023. Hafter reset and retry I witnessed the system attempt to cycle on once and shut right back off within 2 to 3 seconds almost like a contractor chattering on and back off. After an additional retry with the system running the equipment appeared to be functioning properly with the FP1 sensor stable at 25 to 28° in low stage heat. After switching to high stage heat The system ran good for 30 seconds to 1 minute until it instantly dropped off to -3°f within two or three seconds and proceeded to lock out again on FP1. After investigating the control boards, wiring, sensors, and installing refrigerant gauges and water temperature sensors The system turned on and ran normal and exactly to book specs including refrigerant pressures, superheat and subcooling, water temperature drop and air temperature rise. All perfect to 30° wat
Install new Daikin FIT HVAC system Furnace: DM80VC0804CN Serial: 2407108381 Heat Pump: DZ6VSA421E Serial: 2310269083 Coil: CAPEA6030D4 Serial: 2408191060 Daikin One communicating thermostat: DTST-TOU-A Serial: EA2405006295 AprilAire 1210 (20x25) Media Air Cleaner * Replace Return Air Drop * Additional Return and Supply Duct Modification * Reconnect to existing gas line and electric * Transition to existing supply and return ductwork * Start up and commission new system 12 Year Daikin manufacturers parts warranty (Annual maintenance must be performed) 2 Year Westin Air labor warranty (Annual maintenance must be performed) Lifetime Heat Exchanger Warranty (Annual maintenance must be performed)
Three Waterfurnace 5 series all running in new condition. Individual air filter are in new conditon. Changed this month by Josh. Tested electric strip heat and tested watt usage on each unit. Blower motors are all operating within spec. Tested each unit in geothermal heating aswell. Through Aurora Aid Tool, checked electric strip heat Watt usage, blower motor amp draw, Heat of extraction, compressor Amp draw, and refrigerant pressures. No issues detected for any units while on site today. All systems are properly operating and ready for Winter.
Corinthian will be responsible for the bill due to the fact that the fans are in operating conditions from what I can tell. Shower fan will not come on by the switch. Shower switch actually turns the light and fan off to the toilet room. Concerns for bathroom fan being loud are believed to be caused by the fact that with the shower switch off the bathroom switch will not cycle the bathroom light or the fan unless you turn on the switch at the shower. They said it never made noise prior and now it seems louder than before but that’s because it only works with the shower switch on
Furnace had stored faults for ignition failure. Cleaned flame sensor, checked propane pressure. Adjusted house regulator and set furnace Manifold pressure to 11".
Dispatched for after hours no heat call. Found gas cock shut off. Open gas tested operation. Set Vision Pro 8000 to 2 deg droop and 4 hr Aux timer. Explained operation to customer. System operating correct at this time. Removed diag fee and consider this a one time free inspection after construction.
Electric heating preventative maintenence inspection on three Waterfurnace 7Series geothermal units and Desert Aire pool unit. All three Waterfurnace units running in great condition. All 30x32x2 air filters in good condition. All humidifier pads in good condition. Geo #2 humidifier power was not hooked up. Verified proper low voltage wiring and thermostat programming. Beth got an extention cord and we plugged it in. All humidifiers are operational. Flushed coil drain traps to clear debris. Test ran units in emergency heating mode to analyze electric heating strips. All units are properly operating in EM-Heat. Test ran units in geothermal heating mode to verify operation. All units are properly operating in geothermal heating shown from Aurora Aid Tool. All ground loop systems are operating at ~45psi inlet pressure when running at 100% speed. Desert Aire system is operating in great condition. Filters changed on 11-2. Electric heating package is operating properly.
2022 WaterFurnace 7 Series NVV 036 serial number 220601654 has a failed suction line temperature thermistor AXB has entered safe mode operation at 40% capacity Equipment had 50+ E4- FP2 service codes and 30 Plus e72 suction temperature sensor service codes Suction temperature display on aid tool is reading -112° causing 100% shut down of electronic expansion valve Equipment is now running in "Safemode" until thermister is replaced, service codes are cleared, and high voltage is cycled Three system 7 series package equipment heating PMI Accessory maintenance service 2x April e100 whole house dehumidifiers, 2x aprilaire 700 power humidifiers, aprilaire 8100 whole house ERV fresh air ventilator Melissa ordered warranty water furnace parts online Office staff will contact homeowners to reschedule repair services Humidifiers need replacement #35 water panels to complete the winter preseason inspection, tune up & cleaning Homeowner is responsible for inspecting and or replacing air fil
fixed water leak on a new construction home. Carrier air conditioner.
Desert Aire System Installed in a Pool House for a Customer.
Carrier Furnace Installed in a new Construction house.