I dread hiring contractors because it seems things never go as discussed or that corners get cut. I was so happy when Westin changed my furnace and ac because not only did it go just as discussed, the work was clean and meticulous and the workers were professional. The price was better than other quotes I got (from the companies with the high dollar tv and radio ads you always see). I definitely will recommend them to friends and family.
Pediatric office: Dial set screw for the thermostat had come loose. Tightened it up. Ceiling electric heater now operating normally.
Did not dispatch. Said they’ll wait till Monday calling an electrician first due to possibly bad panel
2019 Carrier high efficiency furnace running in great condition. 20x25x1 air filter in good condition. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. 2" pvc flue in good condition and no sign of leaks. 0PPM CO detected during testing in basement. Humidifier pad is new today, damper opened, and test ran solenoid operation. Furnace test ran in heating mode. Delta t of 58F with supply temp of 133F, spec Delta t of 40-70F. All systems are operating properly, efficiently and ready for Winter.
Replace faulty heating accessory safety relay Shop-Vac geothermal air handler and flush the drain Service humidifier and address water leaking from humidifier Flush AC condensate drain Install cabinet insulation support in the bottom and the door Install replacement #35 water panel Run test all auxiliary and heat pump modes Change staging differentials in the color touch screen thermostat from .5 .5 .5°f to 3°f diff for auxiliary stage 3 activation Off water pressure in the ground loops is 25 psi Clear all service codes During initial run testing after repairs the 15KW/60 amp electric heat strip pack tripped the 100 amp supply breaker in the main panel feeding the subpanel. Breaker reset and system fired off and ran with heat pump and stage 1 auxiliary until thermostat was satisfied and reduced to stage 1 heat pump only I'll equipment is clean safe and ready for winter
Replace 2 existing 2004 Lennox GCS16 RTU units. One 4 ton and one 3 Ton. Install new Bryant gas/electric package unit Model # system 1: 582KP05A150A3A0AC (4Ton) Model # system 2: 582KP04A110A3A0AC (3Ton) Installation: *Manual outside air damper *Curb transition *Reconnect to existing gas line *Reconnect to existing high voltage circuit *Crane rental *HVAC permit Warranty: Manufacturers parts warranty 1 Year Westin Air labor warranty
Faulty heat strip relay. EAL15A safety contactor needs replaced Repressurize ground loops from zero psi to 40 PSI, maximum house pressure Test run humidifier, turn on water supply in the basement, discover leaking water from inside the equipment. ***Humidifier needs serviced to stop the leaking water before regular use this season Recommend full system shop vac cleaning Trip charge and ground loop repressurization will be rolled over into the final bill after the strip heat safety relay is replaced Parts are on order awaiting delivery from WaterFurnace Estimate including today's bill has been sent to homeowners for online approval
7.5mfd blower capacitor is reading 2.5mfd and needs replaced. This is causing strain on the blower motor, longer startup and intermittently working conditions. Replaced with new 7.5mfd capacitor. Test ran fan only and heating modes.
Unit A Grove City dental Replace 2 - 20x25x2 filters, visual inspection. Someone else has recently replaced the service disconnect, fan belt, & motor shiv Unit B pediatrics of Grove City Two system RTU package heating equipment tune up, preventive maintenance, filter rotation, safety inspection, cleaning, resurface flame sensor and test electronic ignition system, disassemble for visual inspection of heat exchangers West system 4 - 20x25x2 , East syatem 2 - 20x35x2 Unit C Ohio health work health West system, water inspection, replacement inspection, replace filters, 1 - 20x25x2 Test duct static pressure, return 0.3, supply 0.475 Middle system, install filters 4 - 20x25x2, replace fan belt A35 East system, install replacement air filter 1 - 16X20x2
Upon arrival, thermostat is in off mode. Turned thermostat to heating and set to 90f. Inducer motor comes on instantly as it should. Approximately 10 seconds later the ignitor comes on, and Approximately 5 seconds later, the gas valve opens and the gas is ignited properly. Approximately 3-5 seconds after ignition, the gas valve shuts and the system shuts off. Visual inspection of flame sensor indicates that it is very dirty and possibly not letting the flame seating current to make proper contact. Remove, clean, and replaced flame sensor. Inspected burners to verify they are not rusted or and also causing connection issues. Turned the furnace back on and test ran in heating from thermostat. Furnace comes on as it should and flames stay on thus time. Tested system for 15 images with no issues. Checked Amp draw of both blower and inducer motors, gas valve is getting proper 24v, and pressure switch is satisfied. No other issues detected during testing.
Setting an AC unit for a new construction home.
Carrier Air Conditioner Installed in a New Construction house.
Honeywell Vision Pro 8K Thermostat Installed for a Customer in Grove City.