I dread hiring contractors because it seems things never go as discussed or that corners get cut. I was so happy when Westin changed my furnace and ac because not only did it go just as discussed, the work was clean and meticulous and the workers were professional. The price was better than other quotes I got (from the companies with the high dollar tv and radio ads you always see). I definitely will recommend them to friends and family.
Install New Bryant HVAC System Bryant Legacy Single Stage Gas Furnace 4-Way Multipoise, MCT ECM, Gas Furnace Model #: 800SB36070M14 Serial #: 2025A14406 70,000 BTU's - 80% AFUE - 14" Width Bryant Single-Stage Air Conditioner with Puron Advance Refrigerant, R-454B Model #: GA4SAN52400N Serial #: 1725X17867 2 Ton - 13.4 SEER2 Puron Advance Refrigerant, R-454B Matching Cased Coil: CVAVA2414XMA Serial #: 1925J55194 Installation: * Reconnect to existing gas line and high voltage electric * Transition to existing supply and return ductwork * Start up and commission new system * Honeywell Thermostat Warranty: 20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed) 10 Year Bryant manufacturers Parts & Compressor Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed)
Work health suite Middle Trane unit Switched blower on, noise was very loud. Setup ladder, got on the roof. Removed blower access panel Belt was flopping around. Shut unit down Adjusted belt tension Turned power back on Went back inside the space, all of the employees said it's so much better now. If belt gets loose again, we will need to replaced the motor bracket/tensioner assembly.
Two system rooftop package equipment. Filter inspection, cooling inspection, blower inspection, thermostat inspecti, above ceiling duct inspection, above celing air balance, All equipment is running as expected on the roof. Air filters were replaced in February and are still in very good condition. Confirmed multi-stage cooling on the front system and single stage cooling on the rear system. All blower speeds are set to the factory settings that do have room for adjustments but will require pre-authorization and roof access. The rooms in question for "Tara" are all associated with the thermostat in the front office reception area The back hall thermostat that controls the back of the building system only supplies to the rooms on the east wall. The entire center Island, West wall, and North and South rooms are all on the two-stage large system controlled by the thermostat in the front reception office Air balance to close one of two supply registers in the front reception area and
Everything turns on in the system however the refrigerant pressure has a tiny leak that has allowed the suction pressure to drop to nearly 0psi running but returns to 100+ when turned off. System is nearly empty and will require a full charge with leak stop. 2007 Maratherm R22 equipment. No additional services are supported for r22 equipment. R22 is three generations old and obsolete 2010 ComfortMaker 80% 75K BTU Recommend replacing the equipment ASAP. Leak stop is not guaranteed. The only guarantee in this situation is a leak in the system that could blow out at any time
Heating preventative maintenence inspection on 3 units. Replace all filters and tighten belt on 3rd unit. Clean flame sensors and ignitors. Test run in heating mode to verify proper operation. No issues suspected or found
Mitsubishi VRF system with three air handlers. Throwing low pressure fault. Sent over estimates for finding the leak and the cost for simple repair such as repairing a line set joint.
Pediatric office: Dial set screw for the thermostat had come loose. Tightened it up. Ceiling electric heater now operating normally.
Did not dispatch. Said they’ll wait till Monday calling an electrician first due to possibly bad panel
2019 Carrier high efficiency furnace running in great condition. 20x25x1 air filter in good condition. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. 2" pvc flue in good condition and no sign of leaks. 0PPM CO detected during testing in basement. Humidifier pad is new today, damper opened, and test ran solenoid operation. Furnace test ran in heating mode. Delta t of 58F with supply temp of 133F, spec Delta t of 40-70F. All systems are operating properly, efficiently and ready for Winter.
Replace faulty heating accessory safety relay Shop-Vac geothermal air handler and flush the drain Service humidifier and address water leaking from humidifier Flush AC condensate drain Install cabinet insulation support in the bottom and the door Install replacement #35 water panel Run test all auxiliary and heat pump modes Change staging differentials in the color touch screen thermostat from .5 .5 .5°f to 3°f diff for auxiliary stage 3 activation Off water pressure in the ground loops is 25 psi Clear all service codes During initial run testing after repairs the 15KW/60 amp electric heat strip pack tripped the 100 amp supply breaker in the main panel feeding the subpanel. Breaker reset and system fired off and ran with heat pump and stage 1 auxiliary until thermostat was satisfied and reduced to stage 1 heat pump only I'll equipment is clean safe and ready for winter
Replace 2 existing 2004 Lennox GCS16 RTU units. One 4 ton and one 3 Ton. Install new Bryant gas/electric package unit Model # system 1: 582KP05A150A3A0AC (4Ton) Model # system 2: 582KP04A110A3A0AC (3Ton) Installation: *Manual outside air damper *Curb transition *Reconnect to existing gas line *Reconnect to existing high voltage circuit *Crane rental *HVAC permit Warranty: Manufacturers parts warranty 1 Year Westin Air labor warranty
Faulty heat strip relay. EAL15A safety contactor needs replaced Repressurize ground loops from zero psi to 40 PSI, maximum house pressure Test run humidifier, turn on water supply in the basement, discover leaking water from inside the equipment. ***Humidifier needs serviced to stop the leaking water before regular use this season Recommend full system shop vac cleaning Trip charge and ground loop repressurization will be rolled over into the final bill after the strip heat safety relay is replaced Parts are on order awaiting delivery from WaterFurnace Estimate including today's bill has been sent to homeowners for online approval
7.5mfd blower capacitor is reading 2.5mfd and needs replaced. This is causing strain on the blower motor, longer startup and intermittently working conditions. Replaced with new 7.5mfd capacitor. Test ran fan only and heating modes.